Value Description
U Unconfirmed
P Pending
S Suspect
C Confirmed or verified
I Confirmed but inactive
E Erroneous
D Doubt raised

Anchor
IAM-18
IAM-18

7.3.10.18 IAM-18 Statused by person (XCN) 01563


Components: <ID number (ST)> ^ <family name (ST) > & < last_name_prefix (ST)> ^ <given name (ST)> ^ <middle initial or name (ST)> ^ <suffix (e.g., JR or III) (ST)> ^ <prefix (e.g., DR) (ST)> ^ <degree (e.g., MD) (IS)> ^ <source table (IS)> ^ <assigning authority (HD)> ^ <name type code(ID)> ^ <identifier check digit (ST)> ^ <code identifying the check digit scheme employed (ID )> ^ <identifier type code (IS)> ^ <assigning facility (HD)> ^ < name representation code(ID)>

...

7.3.11.1 ORC-1 Order control (ID) 00215
Anchor
ORC-1
ORC-1

HL7 Table 0119 - Order control codes applicable to REF^I12

Value1

Event/Message Type

Description

Originator2

Field Note3

REREF^I12Observations Performed  

...

  • For MIMS decision support, it's recommended to use the VirtualEntities mapping file to map MIMS pack code to the FastTrack GUID. This file is included in MIMS monthly updates.
  • MIMS ASCII data model has no analog for the AMT MPP concepts.
  • There are some stability concerns with use of MIMS codes:
    1. MIMS pack codes are not guaranteed to be 100% immutable.
    2. Product code may change when the manufacturer elects to split the brand by formulation. In such cases, the old code will be marked as 'off-market' and new codes being issued.
    3. Form code and pack codes are currently 2 digits each. In the event, that more than 99 packs have to be created due to the PBS changes, a new form will be created. The old packs will be marked as 'off market'. This could introduce an issue when trying to re-prescribe a pack.

...